LiteDimmerTM

Parameter Presets

Watch Video or Read Below

Parameter Presets exist for each main parameter, CCT, Accent Color and Saturation. Six factory presets are available at your fingertips. Easily invoke the feature by short-pressing the LEFT screen-side button. Three of the most common presets are offered on the lower line of the display and a slight turn of the LEFT encoder shows additional options. A short-press of the LEFT encoder cycles through parameters. In all, that’s 216 possible combinations that can be customized to match your workflow. To overwrite any factory preset, set the parameter to the desired value, then long-press the associated screen-side button. That’s it.

 

1. Set main 3-position switch to the CENTER position

 

 

2. Press the function button on the display below ‘SETTINGS’

 

 

3. Rotate the left encoder knob to navigate to ‘LOCAL CONTROL’ and press the knob to select it

 

 

4. Rotate the left encoder knob to navigate to ‘OPERATION’ and press the knob to select it.

 

 

5. Rotate the left encoder knob to select one of the three Operation options.

 

 

6. Once Operation option has been selected, turn switch down to control ballast per setting.

 

7. Now press  function button on the display below ‘PRESETS’ to invoke Parameter Presets. A slight turn on the left encoder shows additional options.

 

 

8. 6 factory presets are available for each main parameter (CCT, ACCENT and SAT).

 

 

 

 

9. User can manually exit Parameter Preset screen by simply pressing on left encoder. Screen auto-exits after 10 seconds.